Buy BX8907 Part of Baltimore Transformer Company with NSN 5950-01-240-1103
MPN: BX8907
Manufacturer: Baltimore Transformer Company
NSN: 5950-01-240-1103
Item Name: Transformer Power
CAGE Code: 85323
Part number BX8907 is available for immediate shipping. The NSN for part number is 5950012401103. This part is manufactured by Baltimore Transformer Company. It is described as Transformer Power. Would you like to request a quote for part number BX8907? Please fill out the form.
The form includes various important fields such as your contact details, Need Parts By, and Quantity. Please make sure to fill out all these fields accordingly before clicking to submit the form. Our experts will review your answers for Need Parts By and Quantity to calculate your quote.

Upload RFQ Sheet
If you have more than one item, upload your spreadsheet here
NSN Information for Part Number BX8907 with NSN 5950-01-240-1103, 5950012401103
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-240-1103 Item Description: Transformer Power | 5950 | 012401103 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Bx8907 | 0 | 2 | 3 |
Characteristics Data of NSN 5950-01-240-1103, 5950012401103
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 9.500 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 7.875 INCHES NOMINAL ALL MOUNTING FACILITIES SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 6.500 INCHES NOMINAL ALL MOUNTING FACILITIES SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 12.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 12.125 INCHES NOMINAL |
ABTD | MOUNTING SLOT WIDTH | 0.500 INCHES NOMINAL ALL GROUPINGS |
ACZB | FREQUENCY RATING | 50.0 HERTZ MINIMUM ALL COMPONENTS AND 60.0 HERTZ MAXIMUM ALL COMPONENTS |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 7.5 KILOVOLT-AMPERE ALL COMPONENTS |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE AND BROUGHT OUT TO TERMINAL ALL COMPONENTS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 ALL GROUPINGS |
AXGY | MOUNTING METHOD | TAB ALL GROUPINGS |
BPLC | WINDING FUNCTION AND QUANTITY | 7 PRIMARY ALL COMPONENTS AND 6 SECONDARY ALL COMPONENTS |
CRBZ | WINDING OPERATING CURRENT | 5.0 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY AND 5.0 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY AND 5.0 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY AND 10.0 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
CRMJ | WINDING POWER RATING | 7.5 KILOVOLT-AMPERES SINGLE COMPONENT SINGLE SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 177.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 187.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 198.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND 208.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY AND |
CWJS | WINDING OPERATING VOLTAGE | 40.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY AND 220.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY AND 220.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY AND 235.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDA |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TERMINAL BLOCK W/SCREWS OR 2 SCREW |