Buy 1500-032-2 Part of Eaton Corp with NSN 5925-00-856-4818
MPN: 1500-032-2
Alternate P/N: 15000322
Manufacturer: Eaton Corp
NSN: 5925-00-856-4818
Item Name: Circuit Breaker
CAGE Code: 81640
Part number 1500-032-2 is available for immediate shipping. The NSN for part number is 5925008564818. This part is manufactured by Eaton Corp. It is described as Circuit Breaker. Would you like to request a quote for part number 1500-032-2? Please fill out the form.
The form includes various important fields such as your contact details, Need Parts By, and Quantity. Please make sure to fill out all these fields accordingly before clicking to submit the form. Our experts will review your answers for Need Parts By and Quantity to calculate your quote.

Upload RFQ Sheet
If you have more than one item, upload your spreadsheet here
NSN Information for Part Number 1500-032-2 with NSN 5925-00-856-4818, 5925008564818
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-856-4818 Item Description: Circuit Breaker | 5925 | 008564818 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | S | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
1500-032-2 | 2 | 2 | 5 |
Characteristics Data of NSN 5925-00-856-4818, 5925008564818
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | SINGLE POLE TYPE |
ADAT | BODY WIDTH | 0.750 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.173 INCHES MINIMUM AND 1.203 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1.859 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 1 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING W/PANEL SEAL |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 2.0 AMPERES AC SINGLE LOCATION AND 2.0 AMPERES DC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC SINGLE LOCATION AND 2500.0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | THERMAL SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 PUSH-PULL |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.468 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0.400 MINIMUM AT 200 PCT SINGLE LOCATION AND 1.800 MAXIMUM AT 200 PCT SINGLE LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND MOISTURE RESISTANT |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 25.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
FREQ | FREQUENCY IN HERTZ | 400.0 SINGLE LOCATION |
PKWT | UNPACKAGED UNIT WEIGHT | 0.125 POUNDS |
TTQY | TERMINAL TYPE AND QUANTITY | 2 TAB W/SCREW |
ABXD | BUSHING LENGTH | 0.250 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1.152 INCHES MAXIMUM |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 200.0 AC SINGLE LOCATION AND 28.0 DC SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 150.0 SINGLE LOCATION |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
PMLC | PRECIOUS MATERIAL AND LOCATION | TERMINAL SURFACES SILVER |
PRMT | PRECIOUS MATERIAL | SILVER |
THSD | THREAD SERIES DESIGNATOR | UNS |