Buy 2125312 Part of Navair And Navsea Managed with NSN 5945-00-785-2949
MPN: 2125312
Manufacturer: Navair And Navsea Managed
NSN: 5945-00-785-2949
Item Name: Relay Electromagnet
CAGE Code: 10001
Part number 2125312 is available for immediate shipping. The NSN for part number is 5945007852949. This part is manufactured by Navair And Navsea Managed. It is described as Relay Electromagnet. Would you like to request a quote for part number 2125312? Please fill out the form.
The form includes various important fields such as your contact details, Need Parts By, and Quantity. Please make sure to fill out all these fields accordingly before clicking to submit the form. Our experts will review your answers for Need Parts By and Quantity to calculate your quote.

Upload RFQ Sheet
If you have more than one item, upload your spreadsheet here
NSN Information for Part Number 2125312 with NSN 5945-00-785-2949, 5945007852949
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-785-2949 Item Description: Relay Electromagnet | 5945 | 007852949 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
2125312 | 2 | 2 | 3 |
Characteristics Data of NSN 5945-00-785-2949, 5945007852949
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.030 INCHES NOMINAL |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.624 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABMK | OVERALL WIDTH | 1.140 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 5.000 KILOHMS NOMINAL SINGLE WINDING |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 THREADED STUD SINGLE MOUNTING FACILITY |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
CRXH | TIME DELAY | 0.005 SECONDS NOMINAL FIXED RELEASE TIME |
CRXH | TIME DELAY | 0.013 SECONDS NOMINAL FIXED OPERATE TIME |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 0.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 49.8 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.00 AMPERES AC RESISTIVE LOAD AND 1.00 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE MOUNTING FACILITY |
AAJD | THREAD CLASS | 2A SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 1.270 INCHES NOMINAL |
APNP | DUTY TYPE | CONTINUOUS |