Buy CJD63B400 Part of Siemens Energy And Automation Inc with NSN 5925-01-330-9200
MPN: CJD63B400
Manufacturer: Siemens Energy And Automation Inc
NSN: 5925-01-330-9200
Item Name: Circuit Breaker
CAGE Code: 66842
Part number CJD63B400 is available for immediate shipping. The NSN for part number is 5925013309200. This part is manufactured by Siemens Energy And Automation Inc. It is described as Circuit Breaker. Would you like to request a quote for part number CJD63B400? Please fill out the form.
The form includes various important fields such as your contact details, Need Parts By, and Quantity. Please make sure to fill out all these fields accordingly before clicking to submit the form. Our experts will review your answers for Need Parts By and Quantity to calculate your quote.

Upload RFQ Sheet
If you have more than one item, upload your spreadsheet here
NSN Information for Part Number CJD63B400 with NSN 5925-01-330-9200, 5925013309200
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-330-9200 Item Description: Circuit Breaker | 5925 | 013309200 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Cjd63b400 | 5 | 2 | 3 |
Characteristics Data of NSN 5925-01-330-9200, 5925013309200
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 45.203 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 10.703 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 22.422 INCHES NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AKPX | POLE QUANTITY | 3 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CBBL | FEATURES PROVIDED | ADJUSTABLE TRIP RELEASE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 400.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 600.0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 200000.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | THERMAL-MAGNETIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | INSTANTANEOUS ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF AND FUNGUS PROOF |
CRCF | TRIP RELEASE AMBIENT TEMP RATING | 40.0 DEG CELSIUS NOMINAL ALL LOCATIONS |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
TTQY | TERMINAL TYPE AND QUANTITY | 6 COMPRESSION |
CPSF | ADJUSTABLE TRIP SETTING CURRENT RANGE PER POLE IN AMPS | +2000.0/+4000.0 AC ALL LOCATIONS |
AAQL | BODY STYLE | RECTANGULAR DIMENSIONAL ENVELOPE |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |